Skyline
Kelvin Power

Central Air-Conditioning Series

ISO 9001
ISO 14001
CE
Europe
S
CCC
Central Air Conditioning Unit

Product
Manual

www.kelvinpower.com

2026 Edition
Premium HVAC Solutions info@kelvinpower.com | +974 4444 5555
Company Honor
ISO 14001
ISO 9001
CE Europe
SONCAP
CCC China
Quality Cert
Refrigeration
Production
Certified

Kelvin Power

Brief Introduction

Kelvin Power Air Conditioning Co., Ltd. since we found in 2001, based on social development needs, is committed to upgrade of technological innovation, continuously forge ahead, create new brilliance. Company's products have covered air cooled chiller, water cooled chiller, modular air cooled heat pump, ground source heat pump, ducted type air conditioner, AHU, fan coil unit, and recovery type packaged rooftop unit.

With philosophy of quality is life, our products have passed ISO 9001 international quality system certification, ISO14001 environment system certification and established stringent production inspection. Besides products are insured in quality at PICC and meanwhile export products over CCS, CE, ETL certifications.

Kelvin Power takes "technological innovation, wisdom for future" as the guiding ideology, with high efficient, energy saving and environmental protection for the goal. We already have obtained 6 national invention patents and over 10 utility model patents.

23+
Years Experience
50+
Countries
1000+
Projects
6
Patents
02 03

Content

05
-22
Water/Air Cooled Water Chiller
Water, ground source screw heat pump water chiller, Air cooled screw heat pump water chiller
23
-40
Air Conditioning
Water cooled packaged unit, Air cooled duct split conditioner, Water source heat pump
41
-49
Heat Recovery Fresh Air Handling Unit
Plate type total heat exchange, Rotor type heat recovery fresh air handling unit
50
-58
Airside Equipment
Fan coil unit, Chilled water air handling unit, Assembly air handling unit
59
-65
Dehumidifier & Precision AC
Dehumidifier, Rotor dehumidifier, Room precision air conditioner
66
-70
Heat Pump Chiller for Cooling & Heating
Air-cooled multi water chiller with heat recovery, Hot water supply solution
Premium HVAC Solutions 04
Kelvin-Power Central air-conditioning
Water, Ground-Source Heat Pump
Screw-Type Chiller
Features

① Optimized Design

International standards are fully utilized by anti-modular system design ensure high reliability, large temperature difference and small flow technical idea is able to minimize cost, water consumption and reduce expenses for running.

② Excellent Performance

The main body is equipped with globally advanced semi-hermetic screw compressor, integrating the motor, without worrying about shaft seal leakage. Multiple refrigerating circuits provide flexibility for part-load operation.

③ Wide Scope of Application

Scope of water source temperature applicable for the unit:-8~35°C. The air conditioner cold hot water as well as 50°C hot water can be provided in summer. High temperature unit can provide as high as 60°C hot water.

④ Complete Safety Protection

Pressure protection: High and low pressure protecting devices. Motor protection: Voltage-loss protection, phase-loss protection, inverse phase protection and over-heat protection.

Expressing of Product Models

HWWL: H indicates heat recovery type • W indicates working medium R134a • W indicates R407c and R22 • L indicates water Loop type

Water, Ground-Source
Screw-Water Chiller
Technical Specs
Item HWWLD water, ground-source heat pump screw water chiller(full heat recovery)
HWWLD260R HWWLD300R HWWLD360R HWWLD500R HWWLD620R HWWLD780R HWWLD820R HWWLD950R HWWLD1160R
Heating CapacitykW2553053605006227808209591060
Cooling CapacitykW210250300439520650740795980
Power Supply3N/380V/50Hz
Max Water Temperature°C50~55°C
Cooling Input PowerkW3743517787107120152173
Heating Input PowerkW567279118140178202221243
Matched PowerkW617988130155178220264270
CompressorTypeSemi-Hermetic Screw Compressor
Starting Method25% Load+Star-Delta Reduced Voltage Starting
EvaporatorTypeDry Type Shell And Tube
(Application Side)Chilled Water Flow m³/h3643527690101127136168
Heat Water Flow m³/h27333953678288102125
Water Pressure Drop kPa50~80
CondenserTypeHorizontal Shell And Tube
(water side)Water Flow m³/h27333953678288102125
Water Pressure Drop kPa40~70
Heating capacity kW215255300430520660700815900
Hot Water supply6.17.38.612.315192023.325.8
Full Heat RecoveryHeating capacity kW637590130156195222240300
Hot Water supply m³/h1.82.12.63.74.55.66.36.68.6
RefrigerantR22/R407C/R410A
Volume Kg3436447299110113153
Connection Pipe SizeCondenser2-DN652-DN802-DN802-DN1002-DN1252-DN1252-DN1252-DN1502-DN150
Evaporator2-DN802-DN1002-DN1252-DN1252-DN1252-DN1502-DN1502-DN1502-DN150
Drain valve½"
Unit DimensionL mm260026003000351035103500356038004000
W mm8808901000110011001030123012501300
H mm155015501600180018002500272035502050
WeightNet Weight Kg116012601460255025803140394035503730
Operating Weight Kg1320142017202990314047104400
Noise LeveldB(A)565862656868697070

Attentions: 1. The nominal conditions of refrigerating capacity are: condenser inlet water temperature 18°C, outlet water temperature 29°C, evaporator inlet water temperature 12°C, outlet water temperature 7°C.

2. The nominal conditions of heating capacity are: condenser inlet water temperature 40°C, outlet water temperature 45°C, evaporator inlet water temperature 10°C.

3. The output of heat recovery hot water means the volume flow/rate from 20°C to 50°C.

05 06
Kelvin-Power Central air-conditioning
HWWLDG High-Temperature
Ground-Source Heat Pump
Features

① High Temperature Output

The high-temperature unit can provide hot water up to 65°C, meeting the requirements of domestic hot water and high-temperature heating applications.

② Energy Efficient Design

Advanced heat pump technology provides exceptional COP values, reducing energy consumption and operating costs significantly compared to traditional heating methods.

③ Wide Application Range

Suitable for hotels, hospitals, schools, and commercial buildings requiring both cooling and high-temperature hot water supply simultaneously.

④ Reliable Operation

Built with premium components and comprehensive safety features for long-term stable operation in demanding environments.

Expressing of Product Models

HWWLDG: G indicates high-temperature type • Model number relates to heating capacity

HWWLDG High-Temperature
Ground-Source Chiller
Technical Specs
Item HWWLDG high-temperature water, ground-source heat pump screw water chiller(full heat recovery)
HWWLDG280R HWWLDG320R HWWLDG420R HWWLDG550R HWWLDG680R HWWLDG800R HWWLDG1100DR HWWLDG1360DR HWWLDG1600DR
Heating CapacitykW280330390540690840107013201690
Cooling CapacitykW26030035050063077097712131488
Power Supply3N/380V/50Hz
Max Water Temperature°C60~65°C
Heating Input PowerkW637285116145175212244305
Matched PowerkW708095130165195240280350
CompressorTypeSemi-Hermetic Screw Compressor
Starting Method25% Load+Star-Delta Reduced Voltage Starting
EvaporatorTypeDry Type Shell And Tube
(Application Side)Water Flow m³/h40505982106130148188186
Water Pressure Drop kPa50~80
CondenserTypeHorizontal Shell And Tube
(water side)Water Flow m³/h44545995110116146188196
Heating capacity kW7292110135136146198196210
Hot Water supply2.12.44.344.55.6111113.5
Full Heat RecoveryHeating capacity kW10461101101109104-DN1504-DN150
Hot Water supply m³/h2-DN1252-DN1254-DN1504-DN1504-DN1504-DN1504-DN1504-DN1504-DN150
RefrigerantR134a
Volume Kg7292133144163188198230240
Connection Pipe SizeCondenser2-DN652-DN802-DN1002-DN1002-DN1252-DN1254-DN1504-DN1504-DN150
Evaporator2-DN802-DN1002-DN1002-DN1252-DN1254-DN1504-DN1504-DN1504-DN150
Unit DimensionL mm300030003260356040004000418560007200
W mm86010501600160021002700350035003500
H mm160014002050215021502250235027002790
WeightNet Weight Kg150019802950354041605500610085009500
Noise LeveldB(A)586268687272757878

Attentions: 1. The nominal conditions of refrigerating capacity are: condenser inlet water temperature 30°C, outlet water temperature 35°C, evaporator inlet water temperature 12°C, outlet water temperature 7°C.

2. The nominal conditions of heating capacity are: condenser inlet water temperature 50°C, outlet water temperature 55°C, chiller water temperature: inlet/outlet 10°C.